Jon,
Are you working for a ISV ? I am curious Regards, Scott From: Jon Perryman Sent: Sunday, April 27, 2014 5:46 PM To: IBM Mainframe Discussion List System monitors (e.g. Omegamon) can detect when a job is above or below a specified threshhold. Use your automation product to detect this situation and take the dump / provide notification. If you don't have a monitor, then output from the MVS D A,xxxx command and calculate the difference between the current and previous CT= value. Jon Perryman. ----- Original Message ----- > From: Miklos Szigetvari <[email protected]> > > O.k. so no PFA for this. > It is a test machine, so during the complete "stress test", this was > the only active process, so no WLM or something like this. > Monitored with RMF and the system CPU also dropped to a few percent. > Seems to me , the process is in wait , I would like to get DUMP's and > issue other diag commands in this case. As it happened last time in > Sunday morning 7:30, it would be > not bad to get some kind of alert . ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN