In the general scheme of things defaults in IEASYSxx are LNKAUTH=LNKLST and 
 for CSVLLAxx -LNKLST-
And with no parms a FREEZE is done on all LNKLST. Guess I could see where  
updates could get out of
SYNC.
 
>From !.13 Init and Tuning ref.:
<--- quote --->
 
-LNKLST- can be used to designate a list of data  sets for this parameter, 
which is derived from all active LNKLST sets. When specified, LLA  builds 
this list for you as part of its normal processing. It is a shorthand way  to 
identify all of the data sets in the LNKLST instead of listing each of them  
using (-LNKLST-,  non-LNKLST libname1, non-LNKLST libname2). As an example, 
specifying FREEZE  (-LNKLST-)  directs LLA to set each of the data sets in 
the LNKLST concatenations list in  FREEZE mode. (LLA provides directories 
from the saved information in LLA storage  for requests via JOBLIB, STEPLIB, 
or TASKLIB.) Specifying NOFREEZE (-LNKLST-)  directs LLA to manage each of 
the data sets (in the LNKLST concatenations list)  in NOFREEZE mode, whenever 
the data set is accessed outside of the LNKLST. That is, LLA provides  
directories by doing I/O to the DASD storage for these data sets specified via  
JOBLIB, STEPLIB, or TASKLIB. However, references to members via any active  
LNKLST concatenation are always provided from LLA storage, so NOFREEZE does 
not  affect that request.
 
<---end  quote --->
 
In a message dated 5/29/2014 9:51:14 A.M. Central Daylight Time,  
[email protected] writes:

It has  already been stated, correctly, that LLA has nothing whatsoever to 
do with  APF authorization. So you could stop LLA and verify that you get 
the same  result. 



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to