I checked in google and found that this feature is available only on z10
and later, but we are running system with z9EC currently . does this still
applicable to us.



On Thu, Jun 19, 2014 at 12:52 PM, Mainframe Mainframe <
[email protected]> wrote:

> We have z/OS 1.13 system in sysplex and now I am adding z/OS 2.1  to be
> part of this.
> So, I have used currently defined couple datasets. But I can see below
> message in syslog.
>
> IXC104I SYSTEM STATUS DETECTION PARTITIONING PROTOCOL ELIGIBILITY: 685
>   SYSTEM CANNOT TARGET OTHER SYSTEMS.
>     REASON: SYSPLEX COUPLE DATA SET NOT FORMATTED FOR THE PROTOCOL
>   SYSTEM IS NOT ELIGIBLE TO BE TARGETED BY OTHER SYSTEMS.
>     REASON: SYSPLEX COUPLE DATA SET NOT FORMATTED FOR THE PROTOCOL
>
>
> When I looked at IXC104I  message it says
>
>
> SYSPLEX COUPLE DATA SET NOT FORMATTED TO SUPPORT PROTOCOL Format primary
> and alternate sysplex couple data sets by specifying the following
> parameters in the input to the IXCL1DSU format utility:
>
> ITEM NAME(SSTATDET) NUMBER(1)
>
> Bring the new couple data sets into service with the appropriate sequence
> of SETXCF COUPLE commands.
>
>
>
> Not much information has been provided on this. I dont find reason to do
> this. Is it really a showstopper for adding z/OS 2.1 with z/OS 1.13
> sysplex.
>
> Anybody faced this issue before. Any alternate way to come out from this
> issue.
>
>

----------------------------------------------------------------------