I trying to display the ACEE of the
Target ASID and don't want it swapped out while I'm in
AR mode

Sent from my iPhone

> On Jul 23, 2014, at 12:02 PM, Rob Scott <[email protected]> wrote:
> 
> Using an ECB for SYSEVENT TRANSWAP implies that the issuer will WAIT on the 
> ECB that will be posted once the TRANSWAP is complete. You are in SRB mode 
> and cannot issue the WAIT SVC - therefore your SRB code has most likely 
> continued before SYSEVENT starts or even completes its processing.
> 
> Also being in SRB mode and using the ECB form of SYSEVENT is probably 
> 'surprising' for the SYSEVENT code, so it might do one of the following :
> 
> (a) Fail gracefully
> (b) Abend
> (c) Attempt to POST the ECB anyway with LINKAGE=SYSTEM/BRANCH hoping that you 
> know what you are doing.....
> 
> In any case I am curious to see which "system address space" are you trying 
> to make NONSWAP and for what purpose?
> 
> 
> Rob Scott
> Lead Developer
> Rocket Software
> 77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA
> Tel: +1.781.684.2305
> Email: [email protected]
> Web: www.rocketsoftware.com
> 
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On 
> Behalf Of MichealButz
> Sent: 23 July 2014 16:34
> To: [email protected]
> Subject: return code from SYSEVENT TRANSWAP ENTRY=BRANCH
> 
> Hi,
> 
> 
> 
> I have a SRB which I schedule in a system address space I would like to make 
> it NON SWAPABLE in the srb I use SYSEVENT TRANSWAP,ENTRY=BRANCH
> 
> Before I prime R1 with a ECB
> 
> 
> 
> The documentation says the return code is in the last byte of R1 when 
> sysevent returns R1 doesn't point to the ECB but some piece of code later in 
> my program
> 
> 
> 
> e.g. LA           R1,ECB
> 
>        SYSEVENT TRANSWAP,LINKAGE=BRANCH
> 
>        CLM     R1,B'0001',=X'00'
> 
>         BE       GOOD
> 
> 
> 
> The address returned in R1 from SYSEVENT points to somewhere in my program 
> not a return code
> 
> 
> 
> Thanks
> 
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
> [email protected] with the message: INFO IBM-MAIN
> ================================
> Rocket Software, Inc. and subsidiaries ■ 77 Fourth Avenue, Waltham MA 02451 ■ 
> +1 800.966.3270 ■ +1 781.577.4321
> Unsubscribe From Commercial Email – [email protected]
> Manage Your Subscription Preferences - 
> http://info.rocketsoftware.com/GlobalSubscriptionManagementEmailFooter_SubscriptionCenter.html
> Privacy Policy - http://www.rocketsoftware.com/company/legal/privacy-policy
> ================================
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to