Hi Folks,
I've been following this thread.
We have some of 32K, some of 1/2 block. BUT, we also have 19069, 6144,
etc. Can I look at the load module size to determine if the module length is
greater than the load library blocksize? Is this a productive use of time?
Thanks!
BobL
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Paul Gilmartin
Sent: Monday, August 11, 2014 3:52 PM
To: [email protected]
Subject: Re: Extents more than One for load modules library [ EXTERNAL ]
On 2014-08-11 15:39, Blaicher, Christopher Y. wrote:
> I have not researched this, at all, so this is an educational question.
>
> From your response to Barry it seems you are saying the Binder will write a
> 32K block and then write a short block on a track?
>
Yes (I have been told).
>If it is doing that, then how is that any better than a Half-track blocksize?
>It is still two blocks per track, or are you saying the binder wastes the
>remainder of the track?
>
It does not waste the remainder of the track. But if Binder needs to write
32760 bytes, then:
o If BLKSIZE=32760, it will write 32760 bytes followed by an IBG.
o If BLKSIZE=27998, it will write 27998 bytes, an IBG, 4762 bytes,
then an IBG. One more interblock gap, and correspondingly less
space for the next block.
The difference is tiny; I'll leave it to the Half-track advocates to concoct a
scenario where Half-track is superior.
And for PDSE, it scarcely matters. Everything is written in 4KiB pages. (But
does Binder know this and ignore the specified BLKSIZE?)
-- gil
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to
[email protected] with the message: INFO IBM-MAIN
This e-mail transmission may contain information that is proprietary,
privileged and/or confidential and is intended exclusively for the person(s) to
whom it is addressed. Any use, copying, retention or disclosure by any person
other than the intended recipient or the intended recipient's designees is
strictly prohibited. If you are not the intended recipient or their designee,
please notify the sender immediately by return e-mail and delete all copies.
OppenheimerFunds may, at its sole discretion, monitor, review, retain and/or
disclose the content of all email communications.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN