You will want to check in the BSDS of the DB2 data sharing group (using offline utility DSNJU004) to determine if there is a STCK to LRSN Delta defined for the data sharing group. This delta is required when a DB2 subsystem is converted to data sharing with a (then) current log RBA that was greater then the high order 6 bytes of the STCK value. If this value is non-zero, it will need to be subtracted from the LRSN value prior to converting it to a timestamp field. ============================================== Wayne Driscoll OMEGAMON DB2 L3 Support/Development wdrisco(at)us(dot)ibm(dot)com All opinions are mine, and do not represent IBM Corporation. ==============================================
IBM Mainframe Discussion List <[email protected]> wrote on 08/18/2014 09:34:06 AM: > From: Arie Kremer <[email protected]> > To: [email protected] > Date: 08/18/2014 09:34 AM > Subject: [IBM-MAIN] Strange LRSN value in DB2 Log Records > Sent by: IBM Mainframe Discussion List <[email protected]> > > We use IFI to analyze DB2 logs. "lrh_time" field in the log record header > is assumed to contain LRSN in SYSPLEX environment, when LRSN is usually > derived from the Coupling Facility clock, i.e. may be be used as a clock. > In most cases, this works perfect. > We have a customer that their Coupling Facility clock and the clock of > other processors are different (5 hours). In their DB2 environment, we get > LRSN that being converting to the timestamp means the year 2038, and seems > as not a clock. The values are acceding, and seems as the problem is only > when interpreting LRSN as a timestamp. > Does somebody know what does it mean? What is this LRSN means and how to > convert it to the real time? > > Many thanks > Arie Kremer > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN