There is no separate SMF record written when data is sent to the JES SPOOL.

And Type 6 records are be written by JES2 or by some SYSOUT processing packages;
some packages that manage spooled output for viewing and/or printing write 
their own SMF User SMF records.

Barry Merrill


Herbert W. "Barry" Merrill, PhD
President-Programmer
MXG Software
Merrill Consultants
10717 Cromwell Drive
Dallas, TX 75229
[email protected]

http://www.mxg.com - FAQ has Most Answers 
[email protected]      - invoices/PO/Payment
[email protected]    - technical
tel: 214 351 1966  - expect slow reply, use email 
fax: 214 350 3694  - prefer email, still works



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Donald J.
Sent: Wednesday, August 20, 2014 1:17 PM
To: [email protected]
Subject: SMF records for SYSOUT file

An SMF type 6 record is created at time a SYSOUT file is printed.  Does anyone 
know if any SMF records are created for the process of writing to the SYSOUT 
file?  
Record type 15 is not written for data sets defined as SYSOUT data sets on DD 
statements.

A user is complaining about a 15 minute delay in her print process showing up 
in the JES3 queue and beginning to print on the VPS printer.  The VPS print 
time matches the SMF 6 record time.

JESYSMSG shows following type output with no timestamps on the messages:
IEF237I JES3 ALLOCATED TO SYSOUT                               
IEF285I   CTTH441.SDB1.JOB07555.D0000032.?             SYSOUT  

--
  Donald J.
  [email protected]

--
http://www.fastmail.fm - Does exactly what it says on the tin

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN