Thanks Pew. The operator may replied for the message and below is the info got from the wait codes manual.
004 The operator entered the VARY XCF,sysname,OFFLINE command to remove the system from the sysplex. Could you please assist how to resolve and bring the system up. Do we need to IPL the system? Thanks.. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Pew, Curtis G Sent: Thursday, August 21, 2014 8:20 AM To: [email protected] Subject: Re: PSW error during IPL On Aug 20, 2014, at 9:40 PM, Meenakshi, Vinoth - CW <[email protected]> wrote: > We IPL'ed our system and we are facing an issue on bringing up the system > with the PSW error. > > "Central processor (CP) 0 is in a nonrestartable stopped state due to a > System Control Program (SCP) initiated reset of the I/O interface for > partition LPAR4. > The disabled wait program status word (PSW) is > 000200008000000000000000000040a2." > > Can anyone please guide me to resolve this issue. You look it up in chapter 3 "Wait state codes" of the MVS System Codes manual. For 0A2 it says: "Cross-system coupling facility (XCF) or cross-system extended services encountered a non-recoverable error and stopped the system. The system also issues this wait state in response to an operator request to stop the system. See z/OS MVS Diagnosis: Reference for information on diagnosing sysplex problems." And under reason code 004 it says: "The operator entered the VARY XCF,sysname,OFFLINE command to remove the system from the sysplex." -- Pew, Curtis G [email protected] ITS Systems/Core/Administrative Services ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN