GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD UI18451 FAILED FOR MODULE
CEEZIDT
IN LMOD CEEPLPKA IN THE SCEERUN LIBRARY. THE RETURN CODE (04)
EXCEEDED THE ALLOWABLE VALUE. DATE 14.247 - TIME 02:35:37 -
SEQUENCE NUMBER 000092 - SYSPRINT FILE SMP00040.
when I checked SMP00040, I didnt find much info except
IEW2322I 1220 1 INCLUDE SMPWRK3(CEEHDSP) UI18451
IEW2322I 1220 2 IDENTIFY CEEHDSP('UI18451')
IEW2322I 1220 3 SETSSI 01118451
<snip>
The SMP/E messages are telling you there was a problem linking load
module CEEPLPKA. Find the binder output for that link edit operation
(literally, Find CEEPLPKA) and you should see something more meaningful
than you've pasted here.
Kurt Quackenbush -- IBM, SMP/E Development
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN