GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD UI18451 FAILED FOR MODULE
CEEZIDT
              IN LMOD CEEPLPKA IN THE SCEERUN LIBRARY. THE RETURN CODE (04)
              EXCEEDED THE ALLOWABLE VALUE. DATE 14.247 - TIME 02:35:37 -
              SEQUENCE NUMBER 000092 - SYSPRINT FILE SMP00040.

when I checked SMP00040, I didnt find much info except

IEW2322I 1220  1    INCLUDE SMPWRK3(CEEHDSP)               UI18451
IEW2322I 1220  2     IDENTIFY CEEHDSP('UI18451')
IEW2322I 1220  3     SETSSI 01118451
<snip>

The SMP/E messages are telling you there was a problem linking load module CEEPLPKA. Find the binder output for that link edit operation (literally, Find CEEPLPKA) and you should see something more meaningful than you've pasted here.

Kurt Quackenbush -- IBM, SMP/E Development

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to