THanks to all. Yes. I that GDG dataset was not catalogged, somehow I missed
to catalog under z/OS 2.1 system.

Thanks alot.

On Mon, Sep 8, 2014 at 10:43 PM, Tony's Basement Computer <
[email protected]> wrote:

> Since all the DCB stuff is there why even specify a model?  I haven't for
> decades.
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Clark, David
> Sent: Monday, September 08, 2014 12:11 PM
> To: [email protected]
> Subject: Re: GDG Job issue
>
>   I think something might have happened to your model - DCB=(GDG,xxxx   See
> if GDG is still cataloged.
>
> David Clark
>
> Brown University
> 3 Davol Sq  Suite B 250
> Providence,  RI  02912-1885
>
> Phone (401) 863-7555
>  Fax     (401) 863-7329
>
> On Mon, Sep 8, 2014 at 1:01 PM, venkat kulkarni <
> [email protected]>
> wrote:
>
> > Hello,
> >          I am running below JCL to take backup of my catalog into PS
> > but not sure, what I am getting this GDG dataset issue.
> >
> >
> > 000001 //MVSLIST      JOB MVSLIST,LISTCAT,CLASS=A,MSGCLASS=A
> > 000002 //LIST     EXEC PGM=IDCAMS,REGION=0M
> > 000003 //SYSPRINT DD DSN=CATLIST.LIST(+1),
> > 000004 //            DISP=(NEW,CATLG,DELETE),
> > 000005 //            DCB=(GDG,LRECL=133,RECFM=VBA,BLKSIZE=5320),
> > 000006 //            SPACE=(CYL,(60,5),RLSE),
> > 000007 //            UNIT=3390,VOL=SER=SMPWK1
> > 000008 //SYSIN    DD DSN=BACK.SYSIN(CATLIST),DISP=SHR
> > 000009 //*
> >
> > O/P
> >
> >  STMT NO. MESSAGE
> >         5 IEFC001I PROCEDURE FTPCATW WAS EXPANDED USING SYSTEM LIBRARY
> > SYS2.PROC ICH70001I VENKAT1  LAST ACCESS AT 08:55:57 ON MONDAY,
> > SEPTEMBER 8, 2014 IEFA107I MVSLIST LIST SYSPRINT - DATA SET
> > CATLIST.LIST.G1006V00 NOT FOUND IEF272I MVSLIST LIST - STEP WAS NOT
> > EXECUTED.
> > IEF373I STEP/LIST    /START 2014251.0938
> > IEF032I STEP/LIST    /STOP  2014251.0938
> >         CPU:     0 HR  00 MIN  00.00 SEC    SRB:     0 HR  00 MIN  00.00
> > SEC
> >         VIRT:     0K  SYS:     0K  EXT:        0K  SYS:        0K
> >         ATB- REAL:                     0K  SLOTS:                     0K
> >              VIRT- ALLOC:       0M SHRD:       0M
> > IEF375I  JOB/MVSLIST /START 2014251.0938 IEF033I  JOB/MVSLIST /STOP
> > 2014251.0938
> >         CPU:     0 HR  00 MIN  00.00 SEC    SRB:     0 HR  00 MIN  00.00
> > SEC
> > --
> >
> >
> >
> > I have GDG defined  in my system like
> >
> > CATLIST.LIST
> > CATLIST.LIST.G1001V00
> > CATLIST.LIST.G1002V00
> > CATLIST.LIST.G1003V00
> > CATLIST.LIST.G1004V00
> > CATLIST.LIST.G1005V00
> >
> >
> > BACK.SYSIN(CATLIST) have entry like
> >
> > LISTCAT ALL CAT(ZOS1A.MASTER.CATALOG)
> > LISTCAT ALL CAT(ZOS1B.MASTER.CATALOG)
> > LISTCAT ALL CAT(ZOS1C.MASTER.CATALOG)
> > LISTCAT ALL CAT(ZOS1D.MASTER.CATALOG)
> > LISTCAT ALL CAT(ZOS21.MASTER.CATALOG)
> >
> > Any clue.
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > email to [email protected] with the message: INFO IBM-MAIN
> >
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email
> to [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to