Hold on a second - you are not coding the ASCB parameter. As stated earlier -I suggest testing with a valid ASCB.
Also - looking at the syntax diagram in the POST description, ERRET only seems to be valid when the ASCB parameter is coded. Rob Scott Lead Developer Rocket Software 77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA Tel: +1.781.684.2305 Email: [email protected] Web: www.rocketsoftware.com -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Gabor Hoffer Sent: 17 October 2014 11:16 To: [email protected] Subject: Re: XM POST ERRET= Yes. MODESET MODE=SUP MODESET EXTKEY=ZERO,SAVEKEY=FOLDKEY,WORKREG=2 * TEST - post an invalid ECB LA R1,1000 invalid ECB * LA R2,2000 invalid ASCB POST (R1),ERRET=error_routine, X MF=(E,EXITPLST),LINKAGE=SYSTEM,ECBKEY=0 On Fri, Oct 17, 2014 at 12:11 PM, Rob Scott <[email protected]> wrote: > Are you PSW Key 0-7 and supervisor state ? > > Rob Scott > Lead Developer > Rocket Software > 77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA > Tel: +1.781.684.2305 > Email: [email protected] > Web: www.rocketsoftware.com > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Gabor Hoffer > Sent: 17 October 2014 10:56 > To: [email protected] > Subject: Re: XM POST ERRET= > > Same result without ASCB parameter, so not XM post. :-( > > On Fri, Oct 17, 2014 at 11:30 AM, Rob Scott > <[email protected]> > wrote: > > > I believe your ERRET routine is not being driven because of the > > invalid ASCB specification. > > > > When you use the ASCB parameter with ERRET, it will only be used > > when the cross-memory POST fails in the address space identified by the > > ASCB. > > > > I would imagine that if the ASCB is invalid, the POST service is > > unable to establish the correct recovery environment and it cannot > > drive > your ERRET. > > > > I would suggest making the ASCB a valid one and retesting your code > > with its bad ECB. > > > > Rob Scott > > Lead Developer > > Rocket Software > > 77 Fourth Avenue . Suite 100 . Waltham . MA 02451-1468 . USA > > Tel: +1.781.684.2305 > > Email: [email protected] > > Web: www.rocketsoftware.com > > > > > > -----Original Message----- > > From: IBM Mainframe Discussion List > > [mailto:[email protected]] On Behalf Of Gabor Hoffer > > Sent: 17 October 2014 09:56 > > To: [email protected] > > Subject: XM POST ERRET= > > > > Hello, > > > > I have problem with ERRET= in POST macro. > > > > example: > > * TEST - post an invalid ECB > > LA R1,1000 invalid ECB > > LA R2,2000 invalid ASCB > > POST (R1),ASCB=(R2),ERRET=error_routine, X > > MF=(E,EXITPLST),LINKAGE=SYSTEM,ECBKEY=0 > > > > Routine (error_routine) won't get called as I post to an invalid > > ECB/ASCB address. Module abends with S602. > > > > As workaround, I use ESTAE, but i don't really like it. > > > > Can anyone send me a working example? > > > > Regards, > > Gabor > > > > -------------------------------------------------------------------- > > -- For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] with the message: INFO > > IBM-MAIN ================================ Rocket Software, Inc. and > > subsidiaries ■ 77 Fourth Avenue, Waltham MA > > 02451 ■ +1 800.966.3270 ■ +1 781.577.4321 Unsubscribe From > > Commercial Email – [email protected] Manage Your > > Subscription Preferences - > > http://info.rocketsoftware.com/GlobalSubscriptionManagementEmailFoot > > er > > _SubscriptionCenter.html > > Privacy Policy - > > http://www.rocketsoftware.com/company/legal/privacy-policy > > ================================ > > > > -------------------------------------------------------------------- > > -- For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] with the message: INFO > > IBM-MAIN > > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ================================ Rocket Software, Inc. and > subsidiaries ■ 77 Fourth Avenue, Waltham MA > 02451 ■ +1 800.966.3270 ■ +1 781.577.4321 Unsubscribe From Commercial > Email – [email protected] Manage Your Subscription > Preferences - > http://info.rocketsoftware.com/GlobalSubscriptionManagementEmailFooter > _SubscriptionCenter.html > Privacy Policy - > http://www.rocketsoftware.com/company/legal/privacy-policy > ================================ > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send > email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ================================ Rocket Software, Inc. and subsidiaries ■ 77 Fourth Avenue, Waltham MA 02451 ■ +1 800.966.3270 ■ +1 781.577.4321 Unsubscribe From Commercial Email – [email protected] Manage Your Subscription Preferences - http://info.rocketsoftware.com/GlobalSubscriptionManagementEmailFooter_SubscriptionCenter.html Privacy Policy - http://www.rocketsoftware.com/company/legal/privacy-policy ================================ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN