Hello folks, We had an issue today where we noticed IEF404I (job end) and IEF403I (job start) messages were not arriving at SYSLOG or NETLOG of a z/OS 1.11 system running in a 4-system sysplex with all others running z/OS 1.13.
Issue started on Nov 26th but was only really discovered today (other than some small automation issues noticed). No IPLs have taken place and no MPF adjustements had been made, IEF404I just suddenly stopped arriving (IEF403I had stopped arriving way before Nov 26th, but it doesn't trigger anything in out automation). We had fixed this by issuing: 1. SETCON MONITOR,JOBNAMES=(OFF) 2. SETCON MONITOR,JOBNAMES=(ON) >> this command alone didn't work, just worked when issued after the #1 one I also do not see any SETCON MONITOR,JOBNAMES=(OFF) being issued after last IEF404I arrived at our SYSLOG. Have any of you guys seem a behavior like that? Although it's working fine now, I wanted to make sure this won't happen again, so any insight is very much appreciated. Thanks, ------------------------------------------------------------------------------------------------------------------------------- *Lucas Rosalen* [email protected] / *[email protected] <[email protected]>* +55 19 9-8146-7633 ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN