Hi I wonder if anyone can help point me in the right direction.

I have a DCB set up with a DCBE parameter.  I'm running in 31-bit mode and 
I copy the DCB below the line.  On my OPEN I get the following message:

IEC190I xxxxxxxx,yyyyyyyy,dddddddd INVALID DCBE: STORAGE NOT ADDRESSABLE 

Looking at the description of IEC190I is not helping me much.  I've tried 
copying the DCBE below the line and using it from there, I've tried 
keeping it above the line and using it from there, I've tried plugging the 
address into DCBDCBE before the open but the message will just not go 
away.  Strange thing is that the OPEN appears to work but I'm encountering 
an abend later on in processing, which may (or may not) be associated.  My 
routine is an exit routine for a vendor product so I have no real 
information on the abend is associated. 

Any ideas?


Ken MacKenzie 