But if the event happened, is there a way to find out what it was. The slip, I think, would only be helpful if you were anticipating the IEA848I.
Or is the fact this could happen lead one to always have a slip set for IEA848I in case it happens? ;-D Lizette -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Jim Mulder Sent: Saturday, January 17, 2015 3:03 PM To: [email protected] Subject: Re: AW: Re: How to find which task has been denied to take a dump? > > For IEA848I it says > > > The question was how to find the task that triggered the message > because it is not authorized. It is more general and not restricted > to this specific message: How to find the task related with a > message if ther is no "jobid"? SLIP SET,A=SVCD,MSGID=IEA848I,ML=1,ID=M848,END Jim Mulder z/OS System Test IBM Corp. Poughkeepsie, NY ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN