No. CICS has another TCB which uses z/OS directed LOAD to fetch load modules & program objects. On Jan 21, 2015 5:00 PM, "Paul Gilmartin" < [email protected]> wrote:
> On 2015-01-21 15:12, Greg Dyck wrote: > > > > Normal (non-directed) LOAD processing serializes fetch processing for a > module and only performs relocation of ACONs/VCONs once when the module is > fetched. The only way I could see what you describe happen is if there > were two RLD entries for the same VCON and it would happen with one load or > 20. > > > Does CICS still do its own implementation of LOAD as I understand it > used to in order to circumvent such serialization" Program Objects > would present a challenge. > > -- gil > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN