yes Chris Blaicher Principal Software Engineer, Software Development Syncsort Incorporated 50 Tice Boulevard, Woodcliff Lake, NJ 07677 P: 201-930-8260 | M: 512-627-3803 E: [email protected]
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of [email protected] Sent: Sunday, March 22, 2015 1:32 PM To: [email protected] Subject: Clarification Of STORAGE OBTAIN Parameters Looking for some clarification rearding STORAGE OBTAIN. . . Two Storage OBTAIN Macros STORAGE OBTAIN,LENGTH=(R0),LOC=31,BNDRY=DBLWD STORAGE OBTAIN,LENGTH=(R0),LOC=31,BNDRY=DBLWD,SP=0 My understanding is that If I omit the SP parameter (scenario 1), the system uses a default subpool of 0. Meanning both statements above acquire storage from the same subpool. Is My Assesment Correct ? . . Regarding Common Storage SP253 or SP241 STORAGE OBTAIN,LENGTH=(R0),LOC=31,KEY=(R10),SP=241 When the SP parameter is specified for Common Storage SUbPool, it is My understanding, the Requesting program does not need to be in Supervisor State Key 0 to issue this form of STORAGE OBTAIN, HOWEVER the program does need to be in Supervisor State Key 0 to modify this storage. Is My Assesment Correct ? . . Paul **** ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ________________________________ ATTENTION: ----- The information contained in this message (including any files transmitted with this message) may contain proprietary, trade secret or other confidential and/or legally privileged information. Any pricing information contained in this message or in any files transmitted with this message is always confidential and cannot be shared with any third parties without prior written approval from Syncsort. This message is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any use, disclosure, copying or distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and/or Syncsort and destroy all copies of this message in your possession, custody or control. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN