When there is a "symptom dump" (message IEA995I), it contains the
registers at the time of the abend.
Those include
-- length of area (reg 9)
-- address of area (reg 10)
-- return address of caller (reg 14)
SY1 IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=378 REASON CODE=00000014
TIME=07.16.45 SEQ=00013 CPU=4000 ASID=0016
PSW AT TIME OF ERROR 070C1000 81335DB8 ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 01335DB2 - 00181610 0A0D18CE 18FB180C
AR/GR 0: 00000000/00000000_84000000 1: 00000000/00000000_84378000
2: FFFFFFFF/FFFFFFFF_00000040 3: 00000000/FFFFFFFF_00000003
4: FFFFFFFF/FFFFFFFF_005F8588 5: FFFFFFFF/FFFFFFFF_005F8500
6: FFFFFFFF/FFFFFFFF_81330CD0 7: FFFFFFFF/FFFFFFFF_00F53180
8: FFFFFFFF/FFFFFFFF_00000000 9: FFFFFFFF/FFFFFFFF_00000008
A: FFFFFFFF/FFFFFFFF_00556678 B: FFFFFFFF/FFFFFFFF_7FFFDC10
C: FFFFFFFF/FFFFFFFF_00004000 D: FFFFFFFF/00000000_00006008
E: 00000000/00000000_0000702E F: 00000000/00000000_00000014
END OF SYMPTOM DUMP
The registers at time of error ought to be documented in "system codes"
but they are not. I'll see if I can get the VSM owners to address that.
Peter Relson
z/OS Core Technology Design
----------------------------------------------------------------------