I think leap second is "magical". All time measuring devices that respect it - stop for one second to observe it. Do I have it right?
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of George Kozakos Sent: Friday, July 03, 2015 3:43 PM To: [email protected] Subject: Re: Leap Second today! > In my time zone, the leap second occurred at 17:59:60. So, I wonder > about the z/OS STIMER macro: > > If, at 17:59:59 I had issued STIMER WAIT,LT=[18:000:01] > would the wait have expired in 3 seconds? Yes, if you scheduled the leap second via STP or ETR. It would expire in 2 seconds if you aren't using leap seconds > If, at 17:59:59 I had issued STIMER WAIT,BINTVL=[3 seconds] > would the wait have expired at 18:00:01? No, it would expire at 18:00:02 regardless of whether you are using leap seconds > > Unless the answer to both questions is "Yes," there's a bug. > > -- gil George Kozakos z/OS Software Service, Level 2 Supervisor ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN