It's possible to get away with inter-sysplex PDSE sharing for such a long time 
that people forget that it's verboten. I'm told that ISV serialization products 
like MIM do not solve this problem. 

BTW this is a common inhibitor to COBOL V5, which requires PDSE for load 
modules. Many shops have historically shared load libraries across GRS-plex 
boundaries. This may work (indefinitely) for traditional PO. It's deadly for 
PDSE. 

.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Staller, Allan
Sent: Wednesday, July 15, 2015 8:46 AM
To: [email protected]
Subject: Re: Corrupt PDSE

PDSE's *CANNOT*  be shared across SYSPLEX Boundaries. 
PDSE's *CAN* be shared within a SYSPLEX if the SMSPDSE* address spaces are 
running...

HTH,

<snip>

I get below message when i try to access a PDSE dataset, but when I try to 
access the same Dataset from a different SYSPLEX it opens up. We do share the 
Dasd .

IGW702I PDSE Directory Validation Unsuccessful DESC:<ND> Structure is corrupted
LTK:
00000000000000000000000000000000000000000000000000000000000000000000*
ERROR NUM:15
......remainder deleted
</snip>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN