I found this APAR
PK13789: IGD17040I ERROR IN DADSM PROCESSING SAMPLE JOBS CLB3JIV1 AND CLB3JIV2 
UNIT=VIO IS FORBIDDEN WITH DSNTYPE=LIBRARY

http://www-01.ibm.com/support/docview.wss?uid=isg1PK13789

Lizette

-----Original Message-----
>From: Lizette Koehler <[email protected]>
>Sent: Jul 17, 2015 3:17 PM
>To: [email protected]
>Subject: Re: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
>
>So I ran a test with the JCL and change VIO to SYSDA and it worked fine.
>
>I suspect the answer about SMS in your shop redirecting from VIO to DASD may 
>be true.
>
>Lizette
>
>
>-----Original Message-----
>>From: "Farley, Peter x23353" <[email protected]>
>>Sent: Jul 17, 2015 3:13 PM
>>To: [email protected]
>>Subject: Re: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
>>
>>Some shops use ACS routines to convert UNIT=VIO to a "real" DASD allocation, 
>>preferring to use outboard DASD (with all their built-in memory-based cache) 
>>in preference to CEC memory.
>>
>>Perhaps the first LPAR has that policy and your zPDT is configured to use 
>>memory for VIO?
>>
>>Not sure if there really is a restriction from allocating PDSE on VIO, but it 
>>would not surprise me.
>>
>>HTH
>>
>>Peter
>>
>>-----Original Message-----
>>From: IBM Mainframe Discussion List [mailto:[email protected]] On 
>>Behalf Of Roland Kinsman
>>Sent: Friday, July 17, 2015 5:42 PM
>>To: [email protected]
>>Subject: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
>>
>>This JCL...
>>
>>//STEP01 EXEC PGM=IEFBR14 
>>//ALC DD DSN=&&amp;XX00500, 
>>// DISP=(NEW,CATLG,DELETE), 
>>// DSNTYPE=LIBRARY, 
>>// UNIT=VIO, 
>>// DCB=(RECFM=U,LRECL=0,BLKSIZE=27998,DSORG=PO),
>>// SPACE=(CYL,(25,5,200))
>>
>>works fine on one LPAR.  On another LPAR, which happens to be a zPDT, it 
>>fails with the following error messages:
>>
>>IGD17040I ERROR IN DADSM PROCESSING ON VOLUME UNKNWN FOR DATA SET
>> SYS15198.T160706.RA000.HCHRJK0A.XX00500.H01
>> HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
>> IGD306I UNEXPECTED ERROR DURING IGGDAC02 PROCESSING
>> RETURN CODE 12 REASON CODE 144
>> THE MODULE THAT DETECTED THE ERROR IS IGDVTSDA
>> SMS MODULE TRACE BACK - VTSDA VTSCR SSIRT
>> SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00000
>>
>>It seems the key message is...
>>HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
>>
>>Which seems to suggest that PDSE cannot be allocated on VIO.  
>>
>>So why does it work on one LPAR but not the other?
>>
>>It's making me a little crazy.
>>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,