I found this APAR PK13789: IGD17040I ERROR IN DADSM PROCESSING SAMPLE JOBS CLB3JIV1 AND CLB3JIV2 UNIT=VIO IS FORBIDDEN WITH DSNTYPE=LIBRARY
http://www-01.ibm.com/support/docview.wss?uid=isg1PK13789 Lizette -----Original Message----- >From: Lizette Koehler <[email protected]> >Sent: Jul 17, 2015 3:17 PM >To: [email protected] >Subject: Re: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090 > >So I ran a test with the JCL and change VIO to SYSDA and it worked fine. > >I suspect the answer about SMS in your shop redirecting from VIO to DASD may >be true. > >Lizette > > >-----Original Message----- >>From: "Farley, Peter x23353" <[email protected]> >>Sent: Jul 17, 2015 3:13 PM >>To: [email protected] >>Subject: Re: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090 >> >>Some shops use ACS routines to convert UNIT=VIO to a "real" DASD allocation, >>preferring to use outboard DASD (with all their built-in memory-based cache) >>in preference to CEC memory. >> >>Perhaps the first LPAR has that policy and your zPDT is configured to use >>memory for VIO? >> >>Not sure if there really is a restriction from allocating PDSE on VIO, but it >>would not surprise me. >> >>HTH >> >>Peter >> >>-----Original Message----- >>From: IBM Mainframe Discussion List [mailto:[email protected]] On >>Behalf Of Roland Kinsman >>Sent: Friday, July 17, 2015 5:42 PM >>To: [email protected] >>Subject: HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090 >> >>This JCL... >> >>//STEP01 EXEC PGM=IEFBR14 >>//ALC DD DSN=&&XX00500, >>// DISP=(NEW,CATLG,DELETE), >>// DSNTYPE=LIBRARY, >>// UNIT=VIO, >>// DCB=(RECFM=U,LRECL=0,BLKSIZE=27998,DSORG=PO), >>// SPACE=(CYL,(25,5,200)) >> >>works fine on one LPAR. On another LPAR, which happens to be a zPDT, it >>fails with the following error messages: >> >>IGD17040I ERROR IN DADSM PROCESSING ON VOLUME UNKNWN FOR DATA SET >> SYS15198.T160706.RA000.HCHRJK0A.XX00500.H01 >> HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090 >> IGD306I UNEXPECTED ERROR DURING IGGDAC02 PROCESSING >> RETURN CODE 12 REASON CODE 144 >> THE MODULE THAT DETECTED THE ERROR IS IGDVTSDA >> SMS MODULE TRACE BACK - VTSDA VTSCR SSIRT >> SYMPTOM RECORD CREATED, PROBLEM ID IS IGD00000 >> >>It seems the key message is... >>HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090 >> >>Which seems to suggest that PDSE cannot be allocated on VIO. >> >>So why does it work on one LPAR but not the other? >> >>It's making me a little crazy. >> ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN