The overt issue I am having is a S0C1 after doing a POINT macro when the data is on the second volume of a multi-volume (BSAM) dataset. When I first started looking at the issue, I read that an EXTENDED striped dataset would act as though it were on a single volume to the program. I would have to add BLOCKSIZE=LARGE to my DCBE and handle the NOTE/POINT data correctly, but that was about it as far as changes went.
However, when I started looking at the data returned from NOTE, I am getting values of 1, 2, 3, etc. which doesn't quite jive with the documentation (I can't believe everything is on track 0). However, when it (apparently) goes to the second volume, the return value from NOTE starts over at 1. I'm at a loss. Everything I read says this is supposed to work and I am sure I have something missing, I just can't figure out what. Thanks in advance! MARK HAMMACK [email protected] ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN