Have you tried
-+-LOGDATASET-+-(dsn)-'
'-LOGDSNAME--'
LOGDATASET(dsname) | LOGDSNAME(dsname)
specifies an alternate name of a sequential data set used to log the
transmitted data. RECEIVE checks if the data set, specified by the
LOGDATASET/LOGDSNAME operand, is a sequential data set. However, RECEIVE does
not check whether the data set attributes are RECFM=VB, LRECL=255, and
BLKSIZE=3120. If the data set does not exist, the system creates it.
If you specify NONAMES with LOGDATASET or LOGDSNAME, the system does not
search the NAMES data set.
Lizette
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Donald Likens
> Sent: Friday, October 23, 2015 2:23 PM
> To: [email protected]
> Subject: Redirect or hide IEBCOPY output when using the TSO RECEIVE Command
>
> Has anyone figured out how to redirect the IEBCOPY output that is sent as a
> result of
> issuing the TSO RECEIVE command.
>
> Example:
>
> RECEIVE INDA(CNTL.XMIT)
>
> INMR901I Dataset TSSDON.MEAS.PACKAGE.TEMP.CNTL from TSSDON on N1
> INMR906A Enter restore parameters or 'DELETE' or 'END' +
> da(test)
> IEBCOPY MESSAGES AND CONTROL
> STATEMENTS
> PAGE 1
> IEB1135I IEBCOPY FMID HDZ1D10 SERVICE LEVEL UA74515 DATED 20140814
> DFSMS 01.13.00 z/OS 01.13.00 JBB778H CPU 2827
> IEB1035I TSSDON SPFPROCI SPFPROCI 16:12:57 FRI 23 OCT 2015
> PARM='WORK=4M,SIZE=1M'
> COPY INDD=((SYS00486,R)),OUTDD=SYS00484
> IEB1013I COPYING FROM PDSU INDD=SYS00486 VOL=
> DSN=SYS15296.T161257.RA000.TSSDON.R0100739
> IEB1014I TO PDS OUTDD=SYS00484 VOL=VPWRKB DSN=TSSDON.TEST
> IEB167I FOLLOWING MEMBER(S) LOADED FROM INPUT DATA SET REFERENCED BY
> SYS00486
> IEB154I ABEND HAS BEEN SUCCESSFULLY LOADED
> IEB154I ALLOC HAS BEEN SUCCESSFULLY LOADED
> IEB154I APFADD HAS BEEN SUCCESSFULLY LOADED
> IEB154I ASASM HAS BEEN SUCCESSFULLY LOADED
> IEB154I ASMLINK HAS BEEN SUCCESSFULLY LOADED
> IEB154I CALLPRT HAS BEEN SUCCESSFULLY LOADED
> IEB154I CCLB HAS BEEN SUCCESSFULLY LOADED
> IEB154I CCLT HAS BEEN SUCCESSFULLY LOADED
> IEB154I CCL1 HAS BEEN SUCCESSFULLY LOADED
> IEB154I CCOPTF HAS BEEN SUCCESSFULLY LOADED
> IEB154I CCOPTFW HAS BEEN SUCCESSFULLY LOADED
> IEB154I CEEOPTS HAS BEEN SUCCESSFULLY LOADED
> IEB154I CICSLOOP HAS BEEN SUCCESSFULLY LOADED
>
> I want the IEBCOPY print out above to go to a dataset. I have tried
>
> x = OUTTRAP('var.'); // in REXX
> NODISPLAY option
> Reallocating SYSPRINT.
> Reading the manual.
>
> No luck
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,