Thank you. That is the total capacity of the CEC, 28 on my machine. For SCRT 
purposes, I cap at 16. Is there a variable which I can look at to see how far 
under this cap I am, or when I am experiencing capping?

> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]]
> On Behalf Of Werner Kuehnel
> Sent: Monday, October 26, 2015 6:11 AM
> To: [email protected]
> Subject: Re: 4-hour MSU rolling average
> 
> David,
> sorry for the late reply, I was a bit behind with reading ibm-main mails.
> The R4H average for the LPAR is in variable MSU_4H.
> The overall CEC value is in the same control block (RCT) in variable
> RCTCECWU (displacement dec'32' x'20').
> 
> Hth,
> Werner
> 
> 
> 
> Von:    "Gibney, David Allen,Jr" <[email protected]>
> An:     [email protected],
> Datum:  20.10.2015 20:54
> Betreff:        Re: Antwort: 4-hour MSU rolling average
> Gesendet von:   IBM Mainframe Discussion List <IBM-
> [email protected]>
> 
> 
> 
> Which is the value for the LPAR. Is there a similar way to get the overall CEC
> value?
> 
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:IBM-
> [email protected]]
> > On Behalf Of Werner Kuehnel
> > Sent: Tuesday, October 20, 2015 6:21 AM
> > To: [email protected]
> > Subject: Antwort: 4-hour MSU rolling average
> >
> > Here's a little REXX subroutine to get the values:
> >
> > get4hrAvgMSU:
> >    MSU_4H = 0
> >    MSU_GRP = 0
> >    CVT     = C2d(Storage(10,4))              /* point to CVT     */
> >    RMCT    = C2d(Storage(D2x(CVT+604),4))    /* point to RMCT    */
> >    RCT     = C2d(Storage(D2x(RMCT+228),4))   /* Resource Ctrl Tbl*/
> >    MSU_4H = C2d(Storage(D2x(RCT+196),4))    /* 4 hr MSU average */
> >    MSU_GRP = C2d(Storage(D2x(RCT+28),4))     /* Group Limit      */
> >
> > return
> >
> > Werner
> >
> >
> >
> >
> > Von:    Steve Austin <[email protected]>
> > An:     [email protected],
> > Datum:  20.10.2015 14:17
> > Betreff:        4-hour MSU rolling average
> > Gesendet von:   IBM Mainframe Discussion List <IBM-
> > [email protected]>
> >
> >
> >
> > Hi,
> >
> > Is there an API to return this value(s). I'd expected a WLM call, but
> I've not
> > found it yet.
> >
> > Thanks
> >
> > Steve
> >
> > --
> > This e-mail message has been scanned and cleared by Google Message
> > Security and the UNICOM Global security systems. This message is for
> > the named person's use only. If you receive this message in error,
> > please
> delete it
> > and notify the sender.
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to
> > [email protected] with the message: INFO IBM-MAIN
> >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to
> > [email protected] with the message: INFO IBM-MAIN
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send email to