On Tue, 26 Jan 2016 10:36:58 -0800, Charles Mills wrote:
>
>AFAIK, the Binder can do anything that the Linkage Editor can do. In 
>particular, the Binder is perfectly capable of producing a load module, which 
>is stored in a PDS, or a program object, stored in a PDSE or Unix file.
> 
We had a problem, appearing only fairly recently I believe, where a customer
using non-IBM software on non-IBM hardware found load modules produced
 by Binder failing.  Regressing to Linkage Editor resolved the problem.
Customer's vendor's tech support diagnosed it as unexpected (mis-)alignment
of TXT records in the load modules.

-- gil

----------------------------------------------------------------------