Steve, have you ever tried this, or, do you know anyone who has. I tried it and 
I don't seem to be getting control when the volume switches. Here's what I did; 
1) I added LABEL RECORDS ARE STANDARD to the FD for the file. 2) I added a 
DECLARATIVE to process trailer labels for the file. In the code I set the EOF 
switch on and displayed a message. 

When I run the process, it changes tapes (just like before), but I don't get a 
display and it doesn't think it reached EOF.

Any suggestions?

Thanks, Chris

----------------------------------------------------------------------