On Wed, 23 Mar 2016 06:39:40 -0500, Peter Relson <[email protected]> wrote:

>If compiling a REXX exec results in a load module (or program object) and 
>if someone then does a LOAD to access it (or something similar), then the 
>resulting fetch will drive the exit.
>
>I think that those two IF's are not true. Mostly because I don't recall 
>having something that is compiled REXX be RECFM U when in a PDS -- it can 
>be in the same data set as non-compiled REXX execs.

I believe they are true, Peter. RACF's Program Control functions can work for 
compiled REXX execs, for example, when they are turned into load modules. It is 
a two-step process, though: compile, and link-edit, just as for other 
programming languages.

-- 