This:
https://www.ibm.com/support/knowledgecenter/SSLTBW_2.2.0/com.ibm.zos.v2r2.ieaf100/hfourv.htm
seems to say that a z/OS sysplex must reside completely within a single
z/VM system or completely outside it.
<quote>

z/VM is able to simulate advanced Coupling Facility (CF) and Message
Facility (MF) function, namely, the ability of a set of CFs to be directly
connected to one another and to z/OSĀ® guests. z/VM Guest Coupling
Simulation provides for the simulation of one or more complete parallel
sysplexes within a single z/VM system image. The intent is to provide a
pre-production testing platform for a coupled-system installation. The z/VM
simulated environment is not intended for production use because its single
points of failure negate the intent of the parallel sysplex environment.
Other than the processors required, there is no special hardware needed: no
coupling links and no external coupling facilities. Neither is such
hardware supported. *All guest operation systems coupling within a
simulated sysplex can only be coupled (through simulated coupling links) to
coupling facilities also running as guests of the same z/VM system.* Up to
32 virtual machines can be coupled within a simulated sysplex, with each
such virtual machine coupled to up to eight coupling facility virtual
machines. In addition, when the processor and z/VM are so capable, each
simulated coupling facility can connect to up to seven peer simulated
coupling facilities. All coupled guests and simulated coupling facilities
run within a single instance of the z/VM Control Program (CP).

</quote>




On Thu, Apr 14, 2016 at 8:15 AM, Werner Zieleznik <[email protected]>
wrote:

> Hi,
>
> what you're describing is exactly what I tried. It's failing because HCD
> will not allow to define a coupling link from the native CF on the CEC to
> the z/VM LPAR. So the sysplex will not find the path form the old sysplex
> under z/VM to the CF on the CEC.
> Activating the policy with the new CF'S is not a problem as such. But the
> new changes are pending because the link is not found, hence the
> information about the new CF's is not writen to the coupling data sets.
>
> That is exactly the reason for my question here. Has anybody done this
> before, knowing more about z/VM and if that is actually possible.
>
> Thanks
> Werner
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
How many surrealists does it take to screw in a lightbulb? One to hold the
griffon and one to fill the bathtub with brightly colored LEDs.

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN