Willie,

According to the HELP,  the dataset name type defaults to the characteristics 
above. You did not specify directory blocks, so it assumes physical sequential 
(PS). Member names are invalid for PS datasets. Either add directory blocks or 
specify LIBRARY as the dataset name type.

Bob

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of willie bunter
Sent: Friday, April 29, 2016 1:24 PM
To: [email protected]
Subject: Re: SAVING JOB OUTPUT IN A PDSE FROM SDSF

This is what I have.  In the Data set name type   ===>          it is blank as 
shown below.

Data set name  ===> ''SYS2.BATCH.JOBS.OUTPUT' Member to use  ===> JOB06703 
Disposition    ===> SHR        (OLD, NEW, SHR, MOD)                           
                                                                              
Management class     ===>           (Blank for default management class) 
Storage class        ===>           (Blank for default storage class)
  Volume serial      ===>           (Blank for authorized default volume)
  Device type        ===>           (Generic unit or device address) Data class 
          ===>           (Blank for default data class)
  Space units        ===> CYLS      (BLKS, TRKS, CYLS, BY, KB, or MB)
  Primary quantity   ===> 1         (In above units)
  Secondary quantity ===> 5         (In above units)
  Directory blocks   ===>           (Zero for sequential data set)
  Record format      ===> VBA
  Record length      ===> 240
  Block size         ===> 3120 Data set name type   ===>           (LIBRARY, 
blank, ... See Help for more) Extended attributes  ===>           (NO, OPT, or 
blank)                       

--------------------------------------------
On Fri, 4/29/16, Richards, Robert B. <[email protected]> wrote:

 Subject: Re: SAVING JOB OUTPUT IN A PDSE FROM SDSF
 To: [email protected]
 Received: Friday, April 29, 2016, 7:50 AM
 
 Data set name  ===>
 'ABCDE.FGHIJK.LMNOP'                     
         
 Member to use  ===>
 QRSTUV                                   
            
 Disposition
 ===> NEW        (OLD, NEW, SHR, MOD)           
            
            
                                        
                       
 Management
 class     ===>
    (Blank for default management class)  Storage class              ===>
         (Blank for default storage class) 
    
   Volume serial
    ===>           (Blank for
 authorized default volume)
   Device type
             ===>           (Generic
 unit or device address)
 Data
 class                  ===>
    (Blank for default data class)
   Space units              ===>
 CYLS   (BLKS, TRKS, CYLS, BY, KB, or MB) 
    
   Primary quantity
    ===> 25        (In above units)     
                 
   Secondary
 quantity ===> 5          (In above units)       
               
   Directory blocks
    ===> 45        (Zero for sequential
 data set)     <===== Did you specify
 directory blanks???
   Record
 format       ===> FBA               
                              
   Record length        ===> 133     
                                    
    
   Block size
      ===>                       
                          
 Data set name type  ===>
    <======= Do you have this value
 specified???
 Extended attributes  ===>
          (NO, OPT, or blank)           
        
 
 -----Original Message-----
 From: IBM Mainframe Discussion List [mailto:[email protected]]  On 
Behalf Of willie bunter
 Sent: Friday,
 April 29, 2016 7:45 AM
 To: [email protected]
 Subject: Re: SAVING JOB OUTPUT IN A PDSE FROM  SDSF
 
 Lizette,
 
 I tried your suggestion using
 NEW but it doesn't work.  I get the message MEMBER NAME  NOT ALLOWED
 
 I hit the PF1
 option but it wasn't much help.
 --------------------------------------------
 On Thu, 4/28/16, Lizette Koehler <[email protected]>
 wrote:
 
  Subject: Re: SAVING
 JOB OUTPUT IN A PDSE FROM SDSF
  To: [email protected]
  Received: Thursday, April 28, 2016, 7:08 PM
  
  When you use XDC and NEW
  it will indicate if the member already  exists.
  
  You should try
 this and see if
  it works.
 
 
  I find trying
  SHR, OLD
 and NEW on  a PDS that will not matter if it is  over  written a good thing to 
try to understand how things  work.
  
  Also, you could
 press
  PF1 (HELP) and see what the HELP
 panel states.
  
  Lizette
  
  
  >
 -----Original Message-----
  > From: IBM
 Mainframe Discussion List
  [mailto:[email protected]]
  On
  > Behalf Of willie
 bunter
  > Sent: Thursday, April 28, 2016
 4:00 PM  > To: [email protected]  > Subject: SAVING JOB OUTPUT IN A 
PDSE FROM  SDSF  >  > Hallo  All,  >  > I need your  suggestions.  I am savings 
job output in a PDSE using  SDSF.  The  > member name I use is the  job number  
e.g.
  > Member to use  ===>
  JOB067XX
  >
  > I am
  afraid that some
 where down the line I could overwrite a  member because  > the job number 
could be  the same.  Is there  something I could do to prevent  > this from  
happening?
  >
  
  > Below is an example of the screen when  I type XDC beside the job:
  >
  > Data set name  ===>
 
 'SYS2.BATCH.JOBS.OUTPUT
  > Member
 to
  use  ===> JOB06703
 
 > Disposition
  ===> SHR
 (OLD, NEW, SHR, MOD)
  >
 
 > Thanks in
  advance.
 
 > 
  
 
 ----------------------------------------------------------------------
  For IBM-MAIN subscribe / signoff / archive  access instructions,  send email 
to [email protected]  with the message: INFO IBM-MAIN
 
 ----------------------------------------------------------------------
 For IBM-MAIN subscribe / signoff / archive  access instructions, send email to 
[email protected]  with the message: INFO IBM-MAIN
 
 ----------------------------------------------------------------------
 For IBM-MAIN subscribe / signoff / archive  access instructions,  send email 
to [email protected]  with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to