On Wed, May 4, 2016 at 1:01 PM, J R <[email protected]> wrote:

> In light of this confusion, one wonders why the developer opted to format
> the message in hexadecimal.
>

​At the very least, he should have either done a x'????' like HLASM or a
0x???? like C.​



>
> Sent from my iPhone
>
> > On May 4, 2016, at 13:56, Greg Dyck <[email protected]> wrote:
> >
> >> On 5/4/2016 10:41 AM, Carlos Bodra wrote:
> >> SOURCE AND TARGET DEVICE CAPACITIES DO NOT MATCH. CYLINDER CAPACITY OF
> >> SOURCE VOLUME 2721, TARGET VOLUME 0D0B.
> >>
> >> This tells me that source volume has 2721 cylinders and target volume
> >> has 3339 cylinders (0d0b).
> >
> > No, the source volume has 10017 cylinders (x'2727).
> >
> > You need to pick a different target volume to use for the restore.
> > Greg
> >
>



-- 
The unfacts, did we have them, are too imprecisely few to warrant our
certitude.

Maranatha! <><
John McKown

----------------------------------------------------------------------