Indeed, that worked for me, thumbs up! -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Klaus Stanislawiak Sent: Wednesday, July 27, 2016 1:28 AM To: [email protected] Subject: Re: PDSE V2 MaxGen Limit Query
Please have a look at APAR OA43951 and the corresponding solution: > Add a new field to the DFA DFAMAXGN which contains the maximum number > of generations this system supports. With this information it should be possible to access the field in the DFA from REXX. HTH. Klaus Stanislawiak -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Dyck, Lionel B. (TRA) Sent: Tuesday, July 26, 2016 10:06 AM To: [email protected] Subject: PDSE V2 MaxGen Limit Query Is there a way to query the current MAXGENS_LIMIT from the SMS configuration in either REXX or ISPF? I'm looking for a way to prevent a user from specifying a larger maxgen than is allowed in a dialog I'm working on. Thanks ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN