The requirement to keep and archive SYSOUT can be done as follows............
//SYSOUT DD DSN=YOUR.SYSPRINT.GDG.DATASET(+1),DISP=(NEW,CATLG,DELETE),etc,etc The additional requirement to view while the STC is up and running..... ......sorry but retirement has impacted by memory of gadgetry but there's a simple method to write SYSOUT to 2 DD cards, the 2nd of which will be SDSF viewable. Someone younger I hope can chime in. On 8/16/2016 10:09 AM, Nims,Alva John (Al) wrote: > I think there are at least two options: > 1. Since you have already mentioned SDSF, yes I believe you can use SDSF to > copy the output and write it to a GDG, I have done it in the past, but > unfortunately all that code of mine is gone and I no longer have access to > SDSF to help you further. > 2. This is also an option in that is readily available as part of z/OS and > does not require installing any additional software; it does use a UNIQUE > output class (it helps, but is not completely required) that you can start a > JES2 external writer to read the SYSOUT and write to a GDG, you might have to > submit a JOB or start a "Started Task" before leaving the original JOB to do > that, because the SYSOUT must be closed and freed before the external writer > can read the output. > > There is a 3rd option, but ONLY IF you have $AVERS (Software Engineering of > America (SEA)) I think it has options to do this where you do not need a > unique output class and can be done by JOBName, I think, so don't quote me on > that and if you do not already have $AVERS installed, it is a moot point, > unless you are ready to spend money. > > Al Nims > Systems Admin/Programmer 3 > UFIT > University of Florida > (352) 273-1298 > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Jon Bathmaker > Sent: Tuesday, August 16, 2016 10:38 AM > To: [email protected] > Subject: Capturing STC SYSOUT when the STC is shut down > > Hi, > We are running NVAS and the SYSPRINT file gets directed to SYSOUT=* which is > fine as we can browse it if we need to. > > For some reason (Audit request?) I am being asked to vacuum up the SYSOUT > file and put it into a GDG when the task is recycled, while still leaving it > as SYSOUT when the STC is active. . Based on a message I received, a disp > of PASS and SYSOUT are incompatible. I am now considering using SDSF in > batch so solve this problem (thanks to Lorne Heffer). > > Anyone have any ideas? Using a commercial Program Product is a non-starter > as, like everyone else the client is only interested in lower cost. Thanks. > > Regards, > Jon Bathmaker > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, send email to > [email protected] with the message: INFO IBM-MAIN > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN