Does not DECK correspond to SYSPUNCH? And something else (OBJ? LINK?)
correspond to SYSLIN?
CharlesSent from a mobile; please excuse the brevity
-------- Original message --------
From: J R <[email protected]>
Date: 9/24/16 7:57 PM (GMT-08:00)
To: [email protected]
Subject: Re: S99ERROR = 21C For &&OBJ UNIT=VIO
If you specify NODECK you shouldn't need SYSLIN.
Sent from my iPhone
> On Sep 24, 2016, at 22:23, Joseph Reichman <[email protected]> wrote:
>
> I wonder if I can dummy SYSLIN as I just want the assembler listing
>
>
>
>> On Sep 24, 2016, at 10:15 PM, J R <[email protected]> wrote:
>>
>> FM says you can have a DSN :
>>
>> Example: To specify the temporary dsname &LOAD, code: KEY # LEN PARM
>>
>> 0002 0001 0005 50 D3 D6 C1 C4
>>
>> Have you tried UNIT=SYSALLDA?
>>
>> Sent from my iPhone
>>
>>> On Sep 24, 2016, at 22:05, Joseph Reichman <[email protected]> wrote:
>>>
>>> So If I code DALSTATS = 04 and DALNDISP = 04
>>> Which is disp=(NEW,DELETE)
>>>
>>> It should work I don't have a dataset name
>>>
>>> Regardless S99ERROR is 21C
>>>
>>>
>>>
>>>> On Sep 24, 2016, at 9:46 PM, Charles Mills <[email protected]> wrote:
>>>>
>>>> Well, yeah, it has to be temporary -- you can't catalog a dataset in VIO!
>>>>
>>>> SVC 99 will let you allocate a temporary dataset -- I think it was a
>>>> back-reference you were trying to do before? That won't work.
>>>>
>>>> IIRC the basic SVC 99 temporary dataset strategy is to omit the DSN key.
>>>>
>>>> What are you trying to do? Allocate a dataset that will be used in turn by
>>>> two programs that you will call, like an assembler and the binder? That
>>>> works just fine. Just choose a DD name, or let SVC 99 choose one, and pass
>>>> that name to both programs.
>>>>
>>>> You may or may not want to specify UNIT=VIO. I think the usual technique
>>>> these days is to let SMS pick a unit type. It may well pick VIO for a
>>>> temporary dataset.
>>>>
>>>> Charles
>>>>
>>>> -----Original Message-----
>>>> From: IBM Mainframe Discussion List [mailto:[email protected]] On
>>>> Behalf Of Joe Reichman
>>>> Sent: Saturday, September 24, 2016 5:46 PM
>>>> To: [email protected]
>>>> Subject: Re: S99ERROR = 21C For &&OBJ UNIT=VIO
>>>>
>>>> Hi
>>>>
>>>> I have UNIT=VIO
>>>>
>>>> I just read where this can only be specified on a temporary dataset and as
>>>> I have been told I can't do that with SVC 99
>>>>
>>>> ----------------------------------------------
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,