Long before STDATA was the Started Class Table, which was assembled from 
macros. It required an IPL to effect changes. AFAIK that is still supported, 
although I can't imagine any shop still using it. And for non-RACF shops, how 
is the dynamic mechanism implemented in ASM2 and Top Secret?

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-302-7535 Office
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Stephen Donaldson
Sent: Monday, October 10, 2016 7:42 AM
To: [email protected]
Subject: (External):Re: Started task userid

Take a look at the RACF started task table and ICHRIN03. 

“There are in fact two things, science and opinion; the former begets 
knowledge, the latter ignorance.”  --- Hippocrates.

> On 10 Oct 2016, at 15:58, Charles Mills <[email protected]> wrote:
> 
> Consider:
> 
> IEF695I START jjjjjjjj WITH JOBNAME jjjjjjjj IS ASSIGNED TO USER 
> uuuuuuuu, GROUP gggggggg
> 
> How does the system determine uuuuuuuu? In other words, if a shop 
> wanted to change things so that a START for jjjjjjjj was assigned 
> userid vvvvvvvv, where would they specify that?
> 
> Charles


----------------------------------------------------------------------