Hello Peter,

For z/OS it doesn't matter in which STEPLIB library the load module is
loaded from. In other words the entire STEPLIB DD is treated as "one
thing", either APF'd (in case ALL libraries are in APF list) or not (in
case one or more libraries are not in APF list).
The situation you have described sounds WaD (work as designed).

-------------------------------------------------------------------------------------------------------------------------------
*Lucas Rosalen*
Emails: [email protected] / *[email protected]
<[email protected]>*
LinkedIn: http://br.linkedin.com/in/lrosalen
Phone: +48 (71) 792 809 198


2016-11-17 12:59 GMT+01:00 Peter <[email protected]>:

> Hi Group
>
> I have installed a product when I try to start it fails with module not
> being APFed.
>
> There are two datasets in STEPLIB. The Dataset1 which has the failing
> modules is already APFed. Still the STC fails and it was fixed once the
> second dataset was APFed.
>
> I am trying to understand why would STC expect the second dataset in
> steplib in APF though the calling module is in 1st dataset ?
>
> Could some one please explain me ?
>
> Peter
>
> ----------------------------------------------------------------------