Thinking out loud, could you set up XRC (or PPRC) pairing between the older
Hitachi and newer IBM storage devices, and migrate that way? In outline,
you'd (1) swing in the new IBM DS8884, (2) turn on mirroring outbound from
the Hitachi storage unit inbound into the IBM unit, (3) wait until the IBM
unit is all caught up, even while everybody stays happy with their
z/VM-hosted applications and services, (4) quiesce z/VM, (5) wait until the
IBM unit is all caught up again (if XRC), (6) break the pairing and
configure the IBM unit as primary, (7) repoint z/VM to the IBM unit, and
(8) resuscitate z/VM.

I think that all works, but of course check with the vendors. Variations
might be possible that don't require a z/VM service interruption, although
the basic approach described above, if viable, would make it a short one.

The IBM GDPS Virtual Appliance might also be useful in certain migration
scenarios:

http://www.ibm.com/common/ssi/cgi-bin/ssialias?htmlfid=BUD03057USEN

You might also want to read up on z/VM SSI Live Guest Relocation since it
might be useful in certain scenarios.

--------------------------------------------------------------------------------------------------------
Timothy Sipples
IT Architect Executive, Industry Solutions, IBM z Systems, AP/GCG/MEA
E-Mail: [email protected]

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to