Hello Skip , Thanks for sharing your thoughts on this . Appreciate your time and effort to help me out .
The reason for implementing difference is that we have had weird issues on few of the pre-prod systems which are unfortunately a part of the production plex . We wanted to have these systems isolated immediately when there is a problem using SSD or SFM . For now , we have specified lower weights for these systems . We are also looking at a plan to take these LPARS to another sysplex so the production systems are not impacted . Since we did not want to touch anything on existing production couplexx members , thought of asking it here before proceeding . Regards, Baby On Mon, Nov 28, 2016 at 12:04 AM, Jesse 1 Robinson <[email protected]> wrote: > I had to dig into the doc to investigate some of the parameters you're > asking about. Some thoughts: > > -- You do NOT want to use multiple COUPLExx members across the sysplex. > Some of the parameters must be consistent across the plex. If you introduce > multiple COUPLExx members, it's only a matter of time until a change is > made for one system that is not carried over to other systems. I don't know > what effect that might have, but you don't want Level 2 to have to figure > out what went wrong. CLEANUP(nn) for example is specified in COUPLExx. > Different values would mean different COUPLExx members. A risk. > > -- Even parameters that CAN be different across the sysplex should not be > changed just because it's possible. Do you have a strong reason for wanting > different values for INTERVAL or OPNOTIFY? However you set them, I don't > see in the doc any compelling argument for implementing differences. You > can use weighting values in the SFM policy to give priority to beloved cows > at the expense of chickens and goats. You still have a single policy across > the sysplex. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-302-7535 Office > [email protected] > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of baby eklavya > Sent: Saturday, November 26, 2016 12:21 AM > To: [email protected] > Subject: (External):Couplexx values for sysplex - Query > > Hello Listers, > > We are doing a change to set values for INTERVAL ,CLEANUP and OPNOTIFY in > COUPLExx different for few systems in our sysplex . I understand that > INTERVAL can be set different for each system in the plex after you enable > USER INTERVAL on the Functions statement . > > I would be interested to know if you have any thoughts against setting up > different values for CLEANUP on systems within a sysplex . > > Btw , we are on z/os 2.1 and are planning to implement SSD on all systems > within the plex . > > > Regards, > Baby > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN