HSEND DELVOL volser type PURGE IIRC....

________________________________
From: IBM Mainframe Discussion List <[email protected]> on behalf of 
Tony Thigpen <[email protected]>
Sent: Tuesday, December 13, 2016 4:02:06 PM
To: [email protected]
Subject: HSM old tape cleanup

I am looking at my HSM TTOC listing. I have 3 old 3490s that are still
listed. I actually have the tapes, but they are unreadable. On two of
them, I get a label error:
IEC514D DCK OR LBL ERR

On the other one, the TTOC shows:
RC0378I TTOC RECORD AND TAPE MEDIA CONTENTS ARE INCONSISTENT....

Since I can't migrate these volumes, how do I just delete these active
tapes from HSM? They are at least 15 years old so I am not worried about
the data that may have been on them.

--
Tony Thigpen

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN


::DISCLAIMER::
----------------------------------------------------------------------------------------------------------------------------------------------------

The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only.
E-mail transmission is not guaranteed to be secure or error-free as information 
could be intercepted, corrupted,
lost, destroyed, arrive late or incomplete, or may contain viruses in 
transmission. The e mail and its contents
(with or without referred errors) shall therefore not attach any liability on 
the originator or HCL or its affiliates.
Views or opinions, if any, presented in this email are solely those of the 
author and may not necessarily reflect the
views or opinions of HCL or its affiliates. Any form of reproduction, 
dissemination, copying, disclosure, modification,
distribution and / or publication of this message without the prior written 
consent of authorized representative of
HCL is strictly prohibited. If you have received this email in error please 
delete it and notify the sender immediately.
Before opening any email and/or attachments, please check them for viruses and 
other defects.

----------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to