Hi Ravi,
Thanks for the suggestion. We are already running MODE=DUPLEX.
CKPTDEF CKPT1=(DSNAME=SYS1.HASPCKPA,
VOLSER=Z1PG02,
INUSE=YES),
CKPT2=(DSNAME=SYS1.HASPCKPB,
VOLSER=Z1PG03,
INUSE=YES),
DUPLEX=ON,
LOGSIZE=2,
MODE=DUPLEX,
VERSIONS=(NUMBER=0,
WARN=80),
VOLATILE=(ONECKPT=WTOR,
ALLCKPT=WTOR)
Rex
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Ravi Gaur
Sent: Thursday, January 05, 2017 7:52 AM
To: [email protected]
Subject: Re: IPLing z/OS 2.2 from 1.13 for first time getting JES2 catastrophic
error
Also not to miss if you have MODE=DUAL have it changed to MODE=DUPLEX
...There's an APAR regarding it with zOS2.2
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to