Thanks, because of the absence of negative replies, I assume there are not limits. It would be handy if this had been documented.
Kees. > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Jesse 1 Robinson > Sent: 31 January, 2017 20:52 > To: [email protected] > Subject: Re: COUPLExx syntax question. > > Taking the second question (b) first. We code one PATHIN > DEVICE(uuuu,uuuu,uuuu,...) statement that contains all of CTC devices > for all the 'other' members of the sysplex. Same for PATHOUT. I suppose > that you can code as many devices as there are members in the sysplex, > so any limit would be the sysplex size. > > As for question (a), I'm pretty sure there is no limit because we code > one PATHIN STRNAME(xxx) for each sysplex communication structure. There > is no limit on those as the size varies according to CLASS. IBM > recommends a modest number of CLASSes (we have three) but you could > create a whole bunch if you wish. > > Unless someone else has hit a limit in practice, I'm guessing that there > is no architectural limit. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of Vernooij, Kees (ITOPT1) - KLM > Sent: Tuesday, January 31, 2017 6:29 AM > To: [email protected] > Subject: (External):COUPLExx syntax question. > > Hello group, > > Is there a limit on: > > a) The number of PATHIN or PATHOUT statements in COUPLExx? > > b) The number of CTC devnums per PATHIN or PATHOUT > DEVICE(devnum,devnum...) statement? > > Init and Tuning of z/OS V2.2 does mention any limit. > > Thanks, > Kees. > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ******************************************************** For information, services and offers, please visit our web site: http://www.klm.com. This e-mail and any attachment may contain confidential and privileged material intended for the addressee only. If you are not the addressee, you are notified that no part of the e-mail or any attachment may be disclosed, copied or distributed, and that any other action related to this e-mail or attachment is strictly prohibited, and may be unlawful. If you have received this e-mail by error, please notify the sender immediately by return e-mail, and delete this message. Koninklijke Luchtvaart Maatschappij NV (KLM), its subsidiaries and/or its employees shall not be liable for the incorrect or incomplete transmission of this e-mail or any attachments, nor responsible for any delay in receipt. Koninklijke Luchtvaart Maatschappij N.V. (also known as KLM Royal Dutch Airlines) is registered in Amstelveen, The Netherlands, with registered number 33014286 ******************************************************** ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN