On Mon, 13 Feb 2017 20:57:56 +0000, Pommier, Rex <[email protected]> 
wrote:

>All,
>
>Just to circle back and close the issue, I was "barking up the wrong tree" 
>with the IGZ0268W message.  Turns out the driver program that was calling the 
>OS/VS COBOL program had a logic error in it that was calling the wrong program 
>with the wrong parameters.  I don't know why/how it was working on the 1.13 
>system, but a long time ago, the COBOL program that was initiating the abend 
>was replaced by another OS/VS COBOL program.  Unfortunately the developer who 
>wrote the new COBOL program missed one of the calls in the driving ASM 
>program.  Somehow it has chugged along all these years (obviously the COBOL 
>program being called at this one point didn't do anything important) until the 
>OS upgrade.  IBM must have closed a hole in LE maintenance between 1.13 and 
>2.2 and so this logic error that was sliding past now bit us.  Modifying the 
>ASM source to remove the broken call fixed the problem.  Since there are other 
>OS/VS COBOL programs being called by this same ASM driver that are working 
>fine, it wasn't the warning message after all.
>
>Thanks again for all your suggestions and help.
>
>Rex

http://www.computerworld.com/article/3163192/data-center/just-because-it-fails-doesnt-mean-its-a-failure.html

-- 
Dale R. Smith

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN