Paul Gilmartin wrote:
On Wed, 13 Sep 2017 15:52:27 -0300, Clark Morris wrote:

In my opinion PDSE design wasn't and still isn't ready for prime time.
It couldn't and still can't handle SYS1.NUCLEUS and SYS1.LPALIB
because it depends on a started task.  ...

In turn, I'd expect that prohibits program objects in SYS1.LPALIB.


Much of the PDSE code lives in LPALIB. This precludes the use of program objects in any IPL-time LPA list data set. The use of the PDSE started tasks (SMSPDSE and SMSPDSE1) are secondary to being able to build PLPA to begin with.

--
John Eells
IBM Poughkeepsie