It's been forever since I last had to use a 'native' method because I've had 
some form of the PDS command or its ISV descendent to do the fix. StarTool (at 
least) has a 'share' option that allows data set fixes even when a data set is 
allocated. Not needed often and potentially risky, but it makes concurrent 
changes possible when necessary.   

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler 
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Bill Ashton
Sent: Thursday, October 19, 2017 4:38 AM
To: [email protected]
Subject: (External):Re: How to fix blocksize of PDS

Thanks, Skip; I knew I wasn't (totally) losing my mind...I will create a JCL 
member now called FIXBLKSZ and see if I can find it if I need it again!
B

On Wed, Oct 18, 2017 at 6:10 PM, Jesse 1 Robinson <[email protected]>
wrote:

> You remember correctly. In my first IT job as a programmer trainee, I 
> came to be the 'test proclib fixer'. Some yahoo would copy a member 
> into it--specifying incorrect blocksize I suppose--and alter the 
> library's blocksize. I would get a help call. I would run IIRC a dummy 
> IEBUPDATE job with a null SYSUT1 and a SYSUT2 that specified the correct 
> blocksize.
>
> As long as the DSCB blocksize is at least as large as the largest 
> actual member data, no error occurs. But if DSCB is set smaller, 
> attempts to access a larger member gets I/O error. At least that's how it was 
> in 1978.
>
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office ⇐=== NEW
> [email protected]
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] 
> On Behalf Of Bill Ashton
> Sent: Wednesday, October 18, 2017 10:43 AM
> To: [email protected]
> Subject: (External):How to fix blocksize of PDS
>
> Hello friends...I ran some job some time in the past, and it whacked 
> my PDS blocksize (and reset it to the LRECL).
>
> I thought I remembered that there is a slick little job I can run to 
> reset it back to what I need, but I can't remember the particulars. I 
> know it did not involve copying the file, but IIRC, I had only to open 
> the file, and use a disp of old,keep with the correct DCB.
>
> Am I remembering correctly, or is my old brain showing errors?
> Billy
>
> --
> Thank you and best regards,
> *Billy Ashton*


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to