I had similar experience with z196. Used IND$FILE to download to USB. Not only could HMC not process the last byte in the file, it screwed things up so badly that I had to reboot it!
As Doug says, it's easy to fix. Even plain old Notepad works. Just don't leave that last byte hanging there. Unless HMC code has been fixed in the intervening years. Having been bit so badly, I never tried it again on later generations. . . J.O.Skip Robinson Southern California Edison Company Electric Dragon Team Paddler SHARE MVS Program Co-Manager 323-715-0595 Mobile 626-543-6132 Office ⇐=== NEW [email protected] -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Doug Sent: Thursday, November 02, 2017 5:19 PM To: [email protected] Subject: (External):Re: Z14 IOCP and USB Crispin, No z14 here either but on EC12 I found that you could not have CRLF as end of line in the USB file, had to have only LF. I used Notepad++ to change CRLF to LF. Just my 2 cents. Best Regards, Doug .. On Nov 2, 2017, at 16:34, Rob Schramm <[email protected]> wrote: Yea.. discovered the USB limitation as well. The ftp support is seriously deficient. On Thu, Nov 2, 2017, 2:25 PM Jesse 1 Robinson <[email protected]> wrote: > Expanding a bit on the 'right HMC'. There are two PC-like thingies to > choose from: the SE internal to the box, and one or more HMCs in the > CEC network. I believe that when I first tried this on a z196, I went > first to the SE. That did not work. Moved to the nearby HMC, and all was fine. > > But in the spirit of the Ogden Nash doggerel about camels and dromedaries: > or else the other way around. In any case, one works but not the other. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Crispin Hugo > Sent: Thursday, November 02, 2017 10:52 AM > To: [email protected] > Subject: (External):Re: Z14 IOCP and USB > > My fault as I was trying to do it remotely. All appears ok now. > Thanks > > Crispin Hugo > Systems Specialist > Macro 4 Limited > d: +44 1293 872121 | m: +44 7753951308 | t: +44 1293 872000 | > www.macro4.com > > > > Registered office: The Orangery, Turners Hill Road, Worth, Crawley, > West Sussex, RH10 4SS Registered in England no: 00927588 > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of Jesse 1 Robinson > Sent: 02 November 2017 17:15 > To: [email protected] > Subject: Re: Z14 IOCP and USB > > I don't have a z14 to verify, but doing it with earlier Z boxes > requires inserting the USB into the right slot on the right HMC. It > cannot be done via remote login, only on a physical HMC connected to > the CEC. When you insert the USB, a message will pop up on the HMC > confirming that the USB is recognized. That's when the 'upload from > USB' option becomes selectable. If you don't see that message, then > the USB is not recognized. E.g. wrong slot or wrong HMC device. I > think the IOCDS needs to be in the root directory on the USB. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] > On Behalf Of R.S. > Sent: Thursday, November 02, 2017 9:44 AM > To: [email protected] > Subject: (External):Re: Z14 IOCP and USB > > W dniu 2017-11-02 o 17:36, Crispin Hugo pisze: >> Trying to get IOCP onto new Z14 and it seems it only wants me to use >> FTP > and not USB. >> I start on HMC, get over to SE single operations, select I/O > configuration. The USB option is greyed out. >> After I did get one over via FTP(a real pain) after the build , the > source had disappeared. What am I doing wrong. > > It seems you do it properly, at least it worked for 13 and previous > machines. > Wild guesses: > Maybe insert USB stick before you start the dialog? Or just after? > Note, remove any other stick! > Or go to the CPC and logon of SE directly? > > > -- > Radoslaw Skorupka > Lodz, Poland Rob Schramm ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN