I am afraid SYSCONS did not work.


Sent from my Samsung Galaxy smartphone.


-------- Original message --------
From: Jesse 1 Robinson <[email protected]>
Date: 03/11/2017 19:16 (GMT-05:00)
To: [email protected]
Subject: Re: Standalone IPL ADRDSSU and Operating Systems Messages z14

In general for all IPL situations, HMC OpSysMsg is utilized during 'NIP' in two 
situations:

1. The NIP program (loosely, the IPL time code) explicitly directs messages to 
SYSCONS. We do that here for SAD; no 3270 devices are defined. It always works. 
OTOH we have not written a standalone dump tape in years, so I can't say much 
there.

2. All defined 3270 consoles are inaccessible. We use VCC to handle I/O to 
emulated 3270. NIP messages are sent to IODF-defined NIP consoles if at least 
one is accessible. But we've had cases of VCC FUBAR that is not detected by 
NIP. NIP thinks he's talking to a console, but nobody is actually home. The 
only way around this problem is to force the 3270 console chpids offline so 
that NIP will redirect messages to SYSCONS. This is a rare PITA that also 
always works.

The above statements are not dependent AFAIK on hardware level. Same is true 
for z13 (our latest) and all earlier models in my experience. If you don't get 
messages on SYSCONS, look at the standalone restore program definitions and at 
the IOCDS.

.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Crispin Hugo
Sent: Friday, November 03, 2017 3:56 PM
To: [email protected]
Subject: (External):Re: Standalone IPL ADRDSSU and Operating Systems Messages 
z14

I havent done that the nearest machine is in Uk and z14 is in VA. i could not 
see anything in buckets. I can get one done but it will take a few days to get 
here. I need this done this weekend.
Just adrdssu on a jj or jb or jc or ja


Sent from my Samsung Galaxy smartphone.

-------- Original message --------
From: Mark Jacobs - Listserv <[email protected]>
Date: 03/11/2017 18:34 (GMT-05:00)
To: [email protected]
Subject: Re: Standalone IPL ADRDSSU and Operating Systems Messages z14

Have you recreated the iplable tape with the latest level of standalone 
ADRDSSU? Is there anything in the z14 PSP bucket? I'd start with those items.

> Crispin Hugo <mailto:[email protected]> November 3, 2017 at 5:55
> PM I have used the tape many times on zBC12 but when I use it on Z14 ,
> when I go to Operating Systems Messages, I get
> OSM0002 Messages Interface Unavailable.
> I have tried this on HMC and SE and get the same.
>
> I have trawled the manuals and I can't see what has changed or what
> needs to be done.
> As usual any suggestions Welcome
>
> Crispin Hugo
> Systems Specialist
> Macro 4 Limited
> d: +44 1293 872121 | m: +44 7753951308 | t: +44 1293 872000 |
> www.macro4.com<http://www.macro4.com>
> <http://www.macro4.com>
>
>
>
> Registered office: The Orangery, Turners Hill Road, Worth, Crawley,
> West Sussex, RH10 4SS Registered in England no: 00927588
>
> Please consider the environment and only print this email if you
> really need to.
>
> This message (including any attachments) contains confidential
> information that is PRIVILEGED, CONFIDENTIAL and/or ATTORNEY WORK
> PRODUCT and is intended only for the individual(s) named herein. If
> you are not the intended recipient, you are hereby notified that any
> dissemination, distribution or copying of this email is strictly
> prohibited. If you have received this message in error, please notify
> the Macro 4 Postmaster ([email protected]) of the error
> immediately, do not read or use the email and any attachments in any
> manner, destroy all copies, and delete it from your system if the
> communication was sent via email. Macro 4 Limited, Tel: +44 1293
> 872000 Fax: +44 1293 872001.
>
>
>

--

Mark Jacobs
Time Customer Service
Global Technology Services

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

-- 
This e-mail message has been scanned and cleared by Google Message Security 
and the UNICOM Global security systems. This message is for the named 
person's use only. If you receive this message in error, please delete it 
and notify the sender. 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to