On Tue, Dec 5, 2017 at 11:00 AM, Charles Mills <[email protected]> wrote:

> Late to this thread -- sorry.
>
> I am responsible for an STC that is dubbed immediately and that most
> customers start early in the IPL. I have never heard any "you fail because
> OMVS is not up" problems from customers. Perhaps we have just been lucky
> and/or customers have solved it on their own with automation. I have to
> think most of our customers use IPL automation.
>

​No, I made a mistake in my code which _appeared_ to be a UNIX problem
because I didn't zero out some fields.​



>
> Charles
>
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
> Behalf Of Rob Scott
> Sent: Tuesday, December 5, 2017 8:22 AM
> To: [email protected]
> Subject: Re: STC @ IPL - how to wait for OMVS to be initialized with no
> automation product.
>
> If ENFREQ listen for event code 46 is out of the question, you could call
> BPXEKDA for the global OMVS options and wait+retry if you get rc=28
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
I have a theory that it's impossible to prove anything, but I can't prove
it.

Maranatha! <><
John McKown

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN