No, function was only APPLY'd on my z/OS V2R1 system.
BUILDMCS creates this file
++FUNCTION(HPRT200) DESC(Coaxial Printer Support) REWORK(2018010)
/******************************************************************/
/******************************************************************/
/*** THIS MCS FOR FUNCTION HPRT200 WAS CREATED BY THE BUILDMCS ***/
/*** COMMAND ON 2018010 FROM TARGET ZONE Z21T100 ***/
/******************************************************************/
/******************************************************************/ .
++VER(Z038) DELETE(HPRT100) PRE(HOPI705) REQ(HBB7707) SUP(AA15333,
AA21245,AA21665,AA24011,AA24576,HPRT100,UA24854,UA34584,UA38382,UA40012,
UA40893).
++MOD(AOXVTM) DISTLIB(AAOPMOD1) FROMDS(DSN(MCAT.AOP.AAOPMOD1) NUMBER(1))
RMID(UA40893) LMOD(AOXVTM) .
++SAMP(AOXDDEFP) DISTLIB(ASAMPLIB) FROMDS(DSN(MCAT.SYS1.ASAMPLIB)
NUMBER(2)) SYSLIB(SAMPLIB).
++JCLIN CALLLIBS.
//COPY EXEC PGM=IEBCOPY
//SYSIN DD *
COPY OUTDD=SAMPLIB,INDD=ASAMPLIB
//LINK0001 EXEC PGM=IEWBLINK,PARM=('OPTIONS(GENOPTS)')
//GENOPTS DD *
RENT,AMODE=31,RMODE=24
//SYSLMOD DD DSN=LINKLIB
//SYSLIN DD *
ENTRY AOXVTM
INCLUDE AAOPMOD1(AOXVTM) FMID=HPRT200
NAME AOXVTM RC=0
When I try to RECEIVE it:
IEB1135I IEBCOPY FMID HDZ2210 SERVICE LEVEL UA83949 DATED 20170202 DFSMS 02.0
IEB1035I SYSMPREC SMP 08:34:57 WED 10 JAN 2018 PARM='CMWA=256K,SPCLCMOD,WO
COPYMOD OUTDD=SMPTLIB,INDD=SMP00001 SMPTLIB - 1 HPRT200
S M=((AOXVTM,,R)) HPRT200
IEB190I MAXIMUM BLOCK SIZE IS 32760, MINIMUM BLOCK SIZE IS 1024
IEB1013I COPYING FROM PDS INDD=SMP00001 VOL=Z22DLB DSN=AOP.AAOPMOD1
IEB1014I TO PDS OUTDD=SMPTLIB VOL=Z22SMP DSN=SMPE.ZOSR22.HPRT200.F1
IEB1160I OUTPUT DATASET RECFM/LRECL/BLKSIZE COPIED FROM INPUT DATASET
IEB159I NO MEMBERS COPIED FROM INPUT DATA SET REFERENCED BY SMP00001
IEB177I AOXVTM WAS SELECTED BUT NOT FOUND IN ANY INPUT DATA SET
IEB144I THERE ARE 1955 UNUSED TRACKS IN OUTPUT DATA SET REFERENCED BY SMPTLIB
IEB151I JOB HAS TERMINATED WITH ERROR(S)
IEB147I END OF JOB - 4 WAS HIGHEST SEVERITY CODE
Anne D. Crabtree
System Programmer
WV Office of Technology Data Center
1900 Kanawha Blvd East
Bldg 6, Room B-110
Charleston, WV 25305
(304)957-8292
(304)558-1441 fax
Work Hours: 7AM-3PM EST
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Tom Marchant
Sent: Wednesday, January 10, 2018 8:29 AM
To: [email protected]
Subject: Re: AOXVTM module
On Tue, 9 Jan 2018 12:43:37 -0600, Anne Crabtree wrote:
>I did the BUILDMCS from my z/OS V2R1 but the RECEIVE fails because AOXVTM
>module is not in AOP.AAOPMOD1 library.
Was the function accepted on your V2R1 system before you ran the BUILDMCS?
What do the BUILDMCS reports show?
--
Tom Marchant
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to
[email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------