Good thought! Also, is IDENTIFY sensitive to the high-order bit as an AMODE indicator?
Charles -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Tony Harminc Sent: Tuesday, March 20, 2018 3:55 PM To: [email protected] Subject: Re: invalid ENTRY address for IDENTIFY macro On 20 March 2018 at 17:44, Thomas David Rivers <[email protected]> wrote: > I'm having some situations where IDENTIFY "sometimes" > works, but sometimes it gives me a return-code of 12 > in R15. Return code 12 says: > > Entry Address is not within an eligible load module; entry address was > not added. > I'll keep looking - I imagine it's a "head-slapper" - but I was just > wondering if anyone had bumped into this before. Passing IDENTIFY a 24-bit address with some junk in the high byte while in 31-bit mode? ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN