Swaps?

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf 
Of Tony Thigpen
Sent: 04 May 2018 17:47
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: unexpected tape issue with RETAIN

I currently think it has to do with a combination of a faulty tape and a 
mis-configuration in the IODEF, and a testing environment.

Normally, this CPU has no powered-up real tape drives, just a VTL. For some 
testing of new back-up procedures, they wanted me to use a real
3590 so as to not add a bunch of data to the VTL that would then have to be 
replicated.

So, I powered-up and varied on some tape drives. The IODEF thinks they have 
auto-loaders, but they do not. So, I have get a configuration error when I run 
the job on just the first file.

And, since we don't have a lot of spare real 3590 tapes, I have been using the 
same two tapes repeatedly.

I have noticed that the errors only occur on one of the tapes. I think the 
recovery process wants to re-index the tape position but without the 
autoloader, it is failing then the operating system is switching to a new drive.

Tony Thigpen

Lizette Koehler wrote on 05/04/2018 06:12 PM:
> I am not sure if this was covered,
>
> But would the combination of
>
> VOL=REF=*....  and DISP=(,PASS) not work at keeping the tape up?
>
> Lizette
>
>
>> -----Original Message-----
>> From: IBM Mainframe Discussion List <IBM-MAIN@LISTSERV.UA.EDU> On
>> Behalf Of Tony Thigpen
>> Sent: Friday, May 04, 2018 1:32 PM
>> To: IBM-MAIN@LISTSERV.UA.EDU
>> Subject: Re: unexpected tape issue with RETAIN
>>
>> No go. Unit=Aff is only applicable within the same job step.
>>
>> Tony Thigpen
>>
>> Chris Hoelscher wrote on 05/04/2018 04:05 PM:
>>> Unit=aff=step.ddname  ???
>>>
>>> Chris Hoelscher
>>> Technology Architect, Database Infrastructure Services Technology
>>> Solution Services Humana Inc.
>>> 123 East Main Street
>>> Louisville, KY 40202
>>> Humana.com
>>> (502) 476-2538 or 407-7266
>>>
>>>
>>> -----Original Message-----
>>> From: IBM Mainframe Discussion List
>>> [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Tony Thigpen
>>> Sent: Friday, May 4, 2018 3:35 PM
>>> To: IBM-MAIN@LISTSERV.UA.EDU
>>> Subject: [IBM-MAIN] unexpected tape issue with RETAIN
>>>
>>> I have a 50+ step backup job (using real 3590s) that has steps like:
>>>
>>> //STEP049 EXEC PGM=ADRDSSU
>>> //SYSPRINT DD  SYSOUT=*
>>> //DASD     DD  DISP=SHR,UNIT=3390,VOL=SER=HKYTD4
>>> //BACKUP   DD  DSN=DR.T.DSS.HKYTD4.&SUF,DISP=(NEW,KEEP,DELETE),
>>> //             UNIT=3590,VOL=(,RETAIN,REF=*.STEP048.BACKUP),
>>> //             LABEL=(49,SL,RETPD=&DAYS),DCB=(MODEL.DSCB,BLKSIZE=0)
>>> //SYSIN    DD  *
>>>     DUMP FULL INDD(DASD) OUTDD(BACKUP) ALLD(*) ADMIN TOL(IOER) ALLE
>>> /*
>>> //*
>>> //STEP050 EXEC PGM=ADRDSSU
>>> //SYSPRINT DD  SYSOUT=*
>>> //DASD     DD  DISP=SHR,UNIT=3390,VOL=SER=HKYTD5
>>> //BACKUP   DD  DSN=DR.T.DSS.HKYTD5.&SUF,DISP=(NEW,KEEP,DELETE),
>>> //             UNIT=3590,VOL=(,RETAIN,REF=*.STEP049.BACKUP),
>>> //             LABEL=(50,SL,RETPD=&DAYS),DCB=(MODEL.DSCB,BLKSIZE=0)
>>> //SYSIN    DD  *
>>>     DUMP FULL INDD(DASD) OUTDD(BACKUP) ALLD(*) ADMIN TOL(IOER) ALLE
>>> /*
>>>
>>> This job always worked on OS/390 2.10, but under z/OS 1.13,
>>> randomly, when
>> going to a new step, it wants the current tape mounted on a different 3590.
>> Additionally, it does not unload the tape from the first drive.
>>>
>>> Also: If I have only one drive online, it runs to completion. If I
>>> have two
>> drives, but the other one is busy, it runs to completion.
>>>
>>> Info: This system is using RMM as a tape manager, but the files
>>> being
>> created on the tape are not defined in any storage group or RMM.
>>>
>>> It is driving me batty. I have to be 'not seeing' something.
>>>
>>>
>>> --
>>> Tony Thigpen
>>>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
>
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
lists...@listserv.ua.edu with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to