I don't see that term in the IEHDASDR documentation found here:
www.bitsavers.org/pdf/ibm/360/.../GC28-6586-15_OS_Utilities_Rel_21.7_Apr73.pdf
I would guess Change Label In Place
Found an old proc on one of our systems:
BROWSE SYS1.PROCLIB(CLIP) - 01.11
Command ===>
********************************* Top of Data ***************
//CLIP PROC BIN=UNKNOWN
//* S CLIP,BIN=BBBBBB
//*************************************************************
//* THIS PROC IS NO LONGER USEFUL ON THE XA SYSTEM!
//* USE THE DSF PROCS INSTEAD! D24RBH1 06-03-84
//*************************************************************
//CLIPSCAN EXEC PGM=SCAN,
// PARM=(':SYSIN :AEOF :LIT¬&BIN¬ 721 ')
//STEPLIB DD DSN=SYS1.MAINT.LOAD,DISP=SHR
//SYSPRINT DD DUMMY
//IN DD DUMMY
//SYSIN DD DSN=SYS1.PROCLIB(CLIPY),DISP=SHR
//OUT DD DSN=&&CLCTL,DISP=(NEW,PASS),
// UNIT=SYSDA,SPACE=(TRK,(1,1)),DCB=(LRECL=80,BLKSIZE=80,RECFM=F)
//STEP1 EXEC PGM=CLIPWTOR,COND=(16,LT,CLIPSCAN)
//SYSPRINT DD SYSOUT=W
//SYSABEND DD SYSOUT=*
//STMTS DD DSN=&&CLCTL,DISP=(OLD,PASS)
//STEP2 EXEC PGM=IEHDASDR,COND=(16,LT,CLIPSCAN)
//* SYSPRINT DD SYSOUT=W
//SYSPRINT DD DSN=&&CLOUT,DISP=(NEW,PASS),
// UNIT=SYSDA,SPACE=(TRK,(1,1)),DCB=(LRECL=121,BLKSIZE=121,RECFM=F)
//SYSABEND DD SYSOUT=W
//SYSIN DD DSN=&&CLCTL,DISP=(OLD,PASS),UNIT=SYSDA
//LOG1 EXEC PGM=USERLOG,COND=((0,EQ,STEP2),EVEN),
// PARM='+CLIP UNSUCCESSFUL, BIN# = &BIN'
//STEPLIB DD DSN=SYS1.MAINT.LOAD,DISP=SHR
//ERR DD DSN=&&CLOUT,DISP=(OLD,PASS)
//LOG DD DSN=SYS1.PAKDUMP.LOG,DISP=SHR
//SYSIN DD DSN=&&CLCTL,DISP=(OLD,PASS),UNIT=SYSDA
//LOG2 EXEC PGM=USERLOG,COND=((0,LT,STEP2),(16,LT,CLIPSCAN)),
// PARM='+CLIP SUCCESSFUL, BIN# = &BIN'
//STEPLIB DD DSN=SYS1.MAINT.LOAD,DISP=SHR
//LOG DD DSN=SYS1.PAKDUMP.LOG,DISP=SHR
//SYSIN DD DSN=&&CLCTL,DISP=(OLD,PASS),UNIT=SYSDA l
Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp.
Poughkeepsie NY
IBM Mainframe Discussion List <[email protected]> wrote on
05/18/2018 06:16:41 PM:
> From: "Nims,Alva John (Al)" <[email protected]>
> To: [email protected]
> Date: 05/18/2018 06:29 PM
> Subject: Re: CLIP?
> Sent by: IBM Mainframe Discussion List <[email protected]>
>
> Took me a moment to remember what CLIP was, but I do not know if it
> stood for anything.
> Maybe: "Change Label in Perpetuity?" :) [It's Friday, lighten up!]
>
> Al Nims
> Systems Admin/Programmer III
> UF Information Technology
> East Campus
> P.O. Box 112050
> Gainesville, FL. 32611
> (e) [email protected]
> (p) (352) 273-1298
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]
> ] On Behalf Of Jesse 1 Robinson
> Sent: Friday, May 18, 2018 6:09 PM
> To: [email protected]
> Subject: CLIP?
>
> I used the term CLIP (reformat label) today with a colleague who
> clearly did not understand. Isn't it an acronym? I can't find any hits.
>
> .
> .
> J.O.Skip Robinson
> Southern California Edison Company
> Electric Dragon Team Paddler
> SHARE MVS Program Co-Manager
> 323-715-0595 Mobile
> 626-543-6132 Office <===== NEW
> [email protected]<mailto:[email protected]>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN