We have two entries in our ARM Policy, one to start CA OPS/MVS (our automation
Product) and one to start a test version of OPS/MVS. CA-OPS/MVS starts
everything else that needs to be started. Here it is:
DEFINE POLICY NAME(ARMPOLAA) REPLACE(YES)
/*-----------------------------------*/
/* DEFAULT RESTART GROUP */
/*-----------------------------------*/
RESTART_GROUP(DEFAULT)
ELEMENT(*)
RESTART_ATTEMPTS(0)
/*-----------------------------------*/
/* RESTART GROUP FOR CA PRODUCTS */
/*-----------------------------------*/
RESTART_GROUP(CA)
/* CA-OPS/MVS - PRODUCTION */
ELEMENT(OPSS????)
RESTART_ATTEMPTS(3,300) /* 3 ATTEMPS, WITHIN 5 MINUTES */
RESTART_TIMEOUT(900) /* TIMEOUT AFTER 15 MINUTES */
READY_TIMEOUT(900) /* TIMEOUT AFTER 15 MINUTES */
TERMTYPE(ELEMTERM) /* ELEMENT FAILURE NOT SYSTEM */
RESTART_METHOD(ELEMTERM,STC, /* START OPSMAIN WITH */
'S OPSMAIN,SUB=MSTR') /* COMMAND */
/* CA-OPS/MVS - TST1 TEST OPSMVS */
ELEMENT(OPSG????)
RESTART_ATTEMPTS(3,300) /* 3 ATTEMPS, WITHIN 5 MINUTES */
RESTART_TIMEOUT(900) /* TIMEOUT AFTER 15 MINUTES */
READY_TIMEOUT(900) /* TIMEOUT AFTER 15 MINUTES */
TERMTYPE(ELEMTERM) /* ELEMENT FAILURE NOT SYSTEM */
RESTART_METHOD(ELEMTERM,STC, /* START OPSMAIN WITH */
'S OPSGMAIN,SUB=MSTR') /* COMMAND */
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN