We have two entries in our ARM Policy, one to start CA OPS/MVS (our automation 
Product) and one to start a test version of OPS/MVS.  CA-OPS/MVS starts 
everything else that needs to be started. Here it is:

 DEFINE POLICY NAME(ARMPOLAA) REPLACE(YES)

  /*-----------------------------------*/
  /* DEFAULT RESTART GROUP             */
  /*-----------------------------------*/

  RESTART_GROUP(DEFAULT)
    ELEMENT(*)
    RESTART_ATTEMPTS(0)

  /*-----------------------------------*/
  /* RESTART GROUP FOR CA PRODUCTS     */
  /*-----------------------------------*/

  RESTART_GROUP(CA)

  /* CA-OPS/MVS - PRODUCTION           */

    ELEMENT(OPSS????)
      RESTART_ATTEMPTS(3,300)   /* 3 ATTEMPS, WITHIN 5 MINUTES */
      RESTART_TIMEOUT(900)      /* TIMEOUT AFTER 15 MINUTES    */
      READY_TIMEOUT(900)        /* TIMEOUT AFTER 15 MINUTES    */
      TERMTYPE(ELEMTERM)        /* ELEMENT FAILURE NOT SYSTEM  */
      RESTART_METHOD(ELEMTERM,STC, /* START OPSMAIN WITH       */
        'S OPSMAIN,SUB=MSTR')      /* COMMAND                  */

  /* CA-OPS/MVS - TST1 TEST OPSMVS     */

    ELEMENT(OPSG????)
      RESTART_ATTEMPTS(3,300)   /* 3 ATTEMPS, WITHIN 5 MINUTES */
      RESTART_TIMEOUT(900)      /* TIMEOUT AFTER 15 MINUTES    */
      READY_TIMEOUT(900)        /* TIMEOUT AFTER 15 MINUTES    */
      TERMTYPE(ELEMTERM)        /* ELEMENT FAILURE NOT SYSTEM  */
      RESTART_METHOD(ELEMTERM,STC, /* START OPSMAIN WITH       */
        'S OPSGMAIN,SUB=MSTR')     /* COMMAND                  */

----------------------------------------------------------------------